Performance of a petal resonator surface (PERES) coil via equivalent circuit simulation

A.O. Rodríguez, S.E. Solís, M.A. López, M.C. Mantaras, S.S. Hidalgo

Abstract


MRI coil parameters can be estimated via simulation using an equivalent RLC circuit to investigate coil performance. The Spice Opus simulator was used to simulate the loss return coefficients of a circular-shaped coil and a petal resonator surface (PERES) coil via equivalent (RLC) circuit. Simulated coefficient spectra were obtained and compared with experimentally-acquired spectra generated by both coils. From these spectra, resonant modes and quality factors of both coil prototypes were computed at 64 MHz and compared. Impedance and resonant frequency of the 8 petal-PERES coil design were computed and compared against those obtained with the circuit simulation. PERES coil design produced an impedance value of 54 $\Omega$, and an experimental resonant frequency differing by less than 1% from that predicted by the circuit simulator. The quality factor of the coil prototype differs by only 8% from that obtained with the simulation method. Due to construction imperfections in the coil design, it showed a drop of 8.84 dB in attenuation compared with the simulation results obtained with the aid of an equivalent circuit. This scheme may serve as an alternative to the trial-and-error method usually used to develop dedicated RF coils for magnetic resonance imaging.

Keywords


Magnetic resonance imaging; RF coil; simulation; equivalent circuit; quality factor; resonator coil; RLC

Full Text:

PDF

Refbacks

  • There are currently no refbacks.


REVISTA MEXICANA DE FÍSICA, year 67, issue 2, March-April 2021. Bimonthly Journal published by Sociedad Mexicana de Física, A. C. Departamento de Física, 2º Piso, Facultad de Ciencias, Universidad Nacional Autónoma de México, Ciudad Universitaria, Alcaldía Coyacán, C.P. 04510 , Ciudad de México. Apartado Postal 70-348. Tel. (+52)55-5622-4946, https://rmf.smf.mx/ojs/rmf, e-mail: rmf@ciencias.unam.mx. Chief Editor: José Alejandro Ayala Mercado. INDAUTOR Certificate of Reserve: 04-2019-080216404400-203, ISSN: 2683-2224 (on line), 0035-001X (print), both granted by Instituto Nacional del Derecho de Autor. Responsible for the last update of this issue, Technical Staff of Sociedad Mexicana de Física, A. C., Fís. Efraín Garrido Román, 2º. Piso, Facultad de Ciencias, Universidad Nacional Autónoma de México, Ciudad Universitaria, Alcaldía Coyacán, C.P. 04510 , Ciudad de México. Date of last modification, March 1st., 2021.

The responsibility of the materials published in Revista Mexicana de Física rests solely with their authors and their content does not necessarily reflect the criteria of the Editorial Committee or the Sociedad Mexicana de Física. The total or partial reproduction of the texts hereby published is authorized as long as the complete source and the electronic address of the publications are cited.

There is no fee for article processing, submission or publication.

Revista Mexicana de Física by Sociedad Mexicana de Física, A. C. is distributed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License