Rediseño, análisis y simulación mecánica del comportamiento de una lente sólida elástica SEL de apertura máxima

Authors

  • J. González-García Universidad Tecnológica de la Mixteca
  • F. Iturbide-Jiménez Universidad Tecnológica de la Mixteca
  • A. Santiago-Alvarado Universidad Tecnológica de la Mixteca
  • V. H. Castillejos-Reyes Universidad Tecnológica de la Mixteca
  • R. M. Cruz-Sánchez Universidad Tecnológica de la Mixteca
  • V. I. Moreno-Oliva Universidad Tecnológica de la Mixteca
  • E. A. López-López Universidad Tecnológica de la Mixteca

DOI:

https://doi.org/10.31349/RevMexFis.59.6.545

Keywords:

Solid elastic lens, tunable lens, mechanical design of tunable lens

Abstract

One type of adaptive lens known as the Solid Elastic Lens (SEL) is composed mainly of PDMS sylgar 184 elastic body and a mount made of aluminum. Radial forces can be applied to this elastic body thereby allowing the geometric parameters of the lens to change. Previous studies reported the construction and the optical performance of a SEL; the mount of this lens has some inconvenient mechanical drawbacks which cause additional aberrations in the image produced when the entire aperture of the lens is considered. In order to improve the performance of this type of adaptive lens, a study is presented of the optimization and redesign of the mechanical mount to enable the radial forces applied to be more homogenous on the elastic material for maximum aperture of the SEL, as shown in the results of the mechanical analysis done in Solidwork$^{\mbox{\textregistered }}$.

Downloads

Download data is not yet available.

References

N. Sugiura and S. Morita, Appl. Opt. 32 (1993) 4181-4186 DOI: https://doi.org/10.1364/AO.32.004181

B. Berge and J. Peseux, Eur. Phys. J. E3 (2000) 159–163 DOI: https://doi.org/10.1007/s101890070029

L Dong, A K. Agarwal, D J. Beebe & H Jiang, NATURE 442 (2006) 551-554 DOI: https://doi.org/10.1038/nature05024

W. Zhang, K. Aljasem, H. Zappe, and A. Seifert, Opt. Express 19 (2011) 2347-2362 DOI: https://doi.org/10.1364/OE.19.002347

S. Xu, H. Ren, Y. J. Lin, M. G. J. Moharam, S.-T. Wu, and N. Tabiryan, Opt. Express 17 (2009) 17590-17595 DOI: https://doi.org/10.1364/OE.17.017590

N. Chronis, G. L. Liu, K.-H. Jeong, y L. P. Lee, Opt. Express 11 (2003) 2370–2378 DOI: https://doi.org/10.1364/OE.11.002370

R. Arriaga, “Diseño y construccion de un modelo optomecanico del ojo humano utilizando una lente adaptativa” Tesis de Licenciatura, 2008.

S.-Y. Lee, H.-W. Tung, W.-C. Chen, and W. Fang, Proc. IEEE 18 (2006) 2191-2193 DOI: https://doi.org/10.1109/LPT.2006.883891

A. Santiago, S. Vazquez, F. Iturbide, R. Arriaga, and J. Gonzalez, Proc. SPIE 7060 (2008) 706017 DOI: https://doi.org/10.1117/12.795699

A. Santiago, S. Vazquez, F. S. Granados, J. Gonzalez, E. Rueda, and M. Campos, Opt. Eng. 49 (2010) 123401

P. Liebetraut, S. Petsch, W. Monch, and H. Zappe, Appl. Opt. 50 (2011) 3268-3274 DOI: https://doi.org/10.1364/AO.50.003268

U. Karl, E. Steven, Product Design and Development (Mc Graw-Hill, 2008)

G. Pahl, W. Beitz, Engineering Design: A systematic approach (Springer, 1988)

L. D. Miles, Techniques of Value Analysis and Engineering 3ed. (Wendt Commons Library, 1989)

Downloads

Published

2013-01-01

How to Cite

[1]
J. González-García, F. Iturbide-Jiménez, A. Santiago-Alvarado, V. H. Castillejos-Reyes, R. M. Cruz-Sánchez, V. I. Moreno-Oliva, and E. A. López-López, Rediseño, análisis y simulación mecánica del comportamiento de una lente sólida elástica SEL de apertura máxima, Rev. Mex. Fís. 59, (2013).

Most read articles by the same author(s)

Similar Articles

You may also start an advanced similarity search for this article.